Home Phones & Accessories Mobile Phone Screen Protectors Samsung Screen Protectors Galaxy A14 5G Screen Protectors

MOXA Industrial converter ICF-1150-S-SC Industrial RS-232/422/485 to single-mode fiber converter, SC connector, 0 to 60°C opera

FJ $698.29 excl. VAT

MOXA Industrial converter ICF-1150-S-SC Industrial RS-232/422/485 to single-mode fiber converter, SC connector, 0 to 60°C operating temp.

the selected product is not available.

Converters

Description

The ICF-1150 serial-to-fiber converters transfer RS-232/RS-422/RS-485 signals to optical fiber ports to enhance transmission distance. When and ICF-1150 device receives data from any serial port, it sends the data through the optical fiber ports. These products not only support single-mode and multi-mode fiber for different transmission distances, models with isolation protection are also available to enhance noise immunity. The ICF1150 products feature Three-Way Communication and a Rotary Switch for setting the pull high/low resistor for onsite installation.
Three-Way Communication
The ICF-1150 Series supports 2 serial ports, with a DB9 connector for RS-232 communication and a removable terminal block for RS-422 or RS485 communication. The 3 ports (2 serial ports and one fiber port) are completely independent. When an ICF-1150 converter receives data from any one port, it will send the data through the other 2 ports. For example, once the ICF-1150 converter receives a command from the remote master through the fiber port, it will convert the signal and send the command through the RS-232 and RS-422/485 ports at the same time. If the user is monitoring a system running on an RS-485 network, there is no need to use an additional RS-232 to RS-485 converter to connect the laptop computer's serial port to the RS-485 bus.
Rotary Switch for Setting the Pull High/Low Resistor
The RS-485 interface supports multidrop or daisy-chain connections, which system engineers will use to connect serial devices such as meters,RTUs, and readers, together on the same bus. Since the number of serial devices on the same bus will cause the impedance of the data line to increase, the ICF-1150 allows users to tune the pull high/low resistor. Just rotate the switch to the appropriate value without removing the ICF-1150 from the DIN rail.




No. of Ports
2
Serial Standards
RS-232, RS-422, RS-485
Baudrate
50 bps to 921.6 kbps (supports non-standard baudrates)
Flow Control
ADDC® (automatic data direction control) for RS-485
Isolation
2 kV (I models)
Optical Fiber
100BaseFX ports: ICF-1150/1150I-M/S-SC Series: multi-mode/single-mode SC connector ICF-1150/1150I-M/S-ST Series: multi-mode/single-mode ST connector
Pull High/Low Resistor for RS-485
150 kilo-ohm, 10 kilo-ohm, 4.7 kilo-ohm, 3.3 kilo-ohm, 1 kilo-ohm, 909 ohm, 822 ohm,770 ohm, 500 ohm, 485 ohm
RS-485 Data Direction Control
ADDC® (automatic data direction control)
Terminator for RS-485
N/A, 120 ohms, 120 kilo-ohms
Serial Signals
RS-232
TxD, RxD, GND
RS-422
Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w
Data+, Data-, GND
Power Parameters
Input Current
ICF-1150 Series: 127 mA @ 12 VDC ICF-1150I Series: 163 mA @ 12 VDC
Input Voltage
12 to 48 VDC
No. of Power Inputs
1
Overload Current Protection
Supported
Power Connector
Terminal block
Power Consumption
ICF-1150 Series: 163 mA @ 12 VDC ICF-1150I Series: 127 mA @ 12 VDC
Physical Characteristics
Housing
Metal
IP Rating
IP30
Dimensions
30.3 x 70 x 115 mm (1.19 x 2.76 x 4.53 in)
Weight
330 g (0.73 lb)
Installation
DIN-rail mounting
Environmental Limits
Operating Temperature
Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)


Manufacturer Part No:

ICF-1150-S-SC V1.2.0
Brand:

MOXA

Product Type:

-
UPC

-
Product Family:

Industrial converter
Shipping Weight:

0.4 kg
PB Part No:

IPCMXAICF115017
Product Model:

ICF-1150-S-SC



Warranty:
60 months *
* Warranty period is as stated above unless the manufacturer has chosen to specify a longer period.
All warranties are return to base unless otherwise specified.

Questions?

In order to assist us in reducing spam, please type the characters you see:

You may also like