Home Phones & Accessories Smart Watch Accessories Samsung Watch Straps

PowerShield PSCERT2000SB Centurion RT 2000VA / 1800W Short Base Double Conversion True Online UPS Power Factor 0.9 Rack/Tower De

FJ $1,952.93 excl. VAT

PowerShield PSCERT2000SB Centurion RT 2000VA / 1800W Short Base Double Conversion True Online UPS Power Factor 0.9 Rack/Tower Design (2RU) Hot-Swappable Battery. EBM Compatible to Extend Runtime

the selected product is not available.

UPS - Offline / Standby

Description

POWERSHIELD Centurion RT 2000VA / 1800W Short Base Double Conversion True Online UPS. Power Factor 0.9 Rack/Tower Design (2RU) Hot-Swappable Battery. EBM Compatible to Extend Runtime
The Centurion RT features True Online Double Conversion. As our highest single phase power density UPS, this sophisticated range provides the most comprehensive protection for mission-critical devices such as sensitive networks, computers, servers, telecom applications, as well as industrial applications


Exceptional surge protection
Output power factor
Informative & easy-shift LCD display
Rack/Tower design
Programmable outlets
Emergency Power Off Function (EPO)
ECO & advanced ECO mode
Standard extra large charger
Hot swappable batteries
*PSRTBB8 Extended Battery Module not included
Exceptional surge protection Offering the best surge protection in its class to protect against damaging surges
Output power factor The Centurion RT is high-density UPS with output power factor (PF = 0.9) to provide higher performance and efficiency to critical applications.
Informative & easy-shift LCD display The front panel LCD display panel is readily viewable whether the UPS is horizontal or vertical. It displays all critical and noncritical parameters, including remaining battery backup time.
Rack/Tower design The Centurion RT can be easily installed as a floor-standing tower or in a 19-inch rack.
Programmable outlets This UPS comes with programmable power management outlets allowing the user to control the load segments, thereby extending battery backup times to mission critical devices by shutting down non-critical items.
Emergency Power Off Function (EPO) This feature can turn off and isolate the UPS in the event of fires or other emergencies.
ECO & advanced ECO mode It has an advanced ECO mode, which allows the UPS to operate at a very high efficiency, up to 98%. When the utility mains input voltage is within the ECO range the UPS saves energy by passing the mains supply directly through to the load, while the inverter continues to operate in a passive mode.

Standard extra large charger - The Centurion RT has been designed with a larger charger than other UPSs ensuring rapid recharge times when adding additional battery banks. - Long run models available.
Hot swappable batteries Battery banks are hot-swappable. This keeps the UPS operational during battery replacement. Battery banks can be added to increase battery backup time.








Capacity
2000VA/1800W

Topology
True online double- conversion, Pure Sine Wave

Input

Voltage Range

Low Line Transfer:160Vac/140Vac/120/110Vac ±5% (based on load percentage 100%-80%/80%-70%/70%-60%/60%-0)
Low Line Comeback:175Vac/155Vac/135Vac/125Vac ±5 %
High Line Transfer:300Vac ±5 %
High Line Comeback:290Vac ±5 %

Frequency Range
40Hz - 70Hz

Phase
Single-phase with ground

Power Factor Correction
=0.99 @ nominal voltage (100% load)

Output

Output Power Factor
0.9

Output Voltage (AC Mode)
240Vac (Selectable 200/208/220/230/240Vac)

Voltage Regulation (Batt. Mode)
±1%

Frequency Range (Batt. Mode)
50Hz or 60Hz ±1Hz

Current Crest Ratio
3:1 (max.)

Transfer

AC Mode to Batt. Mode: 0 Inverter to Bypass:4ms (Typical)

Waveform (Batt. Mode)

Pure Sine Wave

Efficiency

ECO Mode (Advanced)
97%

Battery Mode
87%

Battery

Battery Number (12 V*9AH)
x4

Typical Recharge Time
4 hours recover to 90% capacity (for standard model only)

Charging Current (max.)
Standard Models - 1.5Amp. Long Run Models - 1Amp/2Amp/4Amp/6Amp selectable (factory default is 6Amp)

Protection

Full Protection
Overload, discharge, thermal, short circuit and overcharge protection

Surge Protection
984 Joules/22000 Amps

Communications and Management

Interface
USB or RS232 as standard, Intelligent slot for PSSNMP, PSModbus or PSAS400 dry contact

Software
PowerShield® NetGuard® software - supports Windows, Linux, Unix and Mac-based operating systems

LCD Display/Alarm
UPS Status, Load & Battery Level, Input/Output Voltage, Batt. Time Remaining and Fault Indicators

Audible Alarm
Battery Mode, Bypass Mode, Low Battery (Batt. Mode), Fault, Overload

Physical

Dimension, (D x W x H) mm
500x 438x 88

Weight (kg)
19.5

Operating Environment

Temperature
0°C~ 40°C

Humidity
20%~ 90% (RH Non-condensing)

Noise Level
<50dBA@1m

Compliance


Safety/EMC/RoHS
EN62040-1-1 2003, IEC60950-1-1/EN62040-2 2006/Directive 2011/65/EU


Manufacturer Part No:

PSCERT2000SB
Brand:

PowerShield

Product Type:

-
UPC

-
Product Family:

-
Shipping Weight:

20.8 kg
PB Part No:

UPSPSD2002
Product Model:

PSCERT2000SB



Warranty:
24 months *
* Warranty period is as stated above unless the manufacturer has chosen to specify a longer period.
All warranties are return to base unless otherwise specified.

Questions?

In order to assist us in reducing spam, please type the characters you see:

You may also like