Home Power & Lighting UPS, PDUs & Alternative Power UPS - On-Line

PowerShield Centurion RT 6000VA Long run model. True On-line double conversion. Rack/Tower UPS. No battery. Includes large inter

FJ $6,172.74 excl. VAT

PowerShield Centurion RT 6000VA Long run model. True On-line double conversion. Rack/Tower UPS. No battery. Includes large internal charger.

the selected product is not available.

UPS - On-Line

Description

-Exceptional surge protection
-Unity output power factor (PF=1)
-Informative & easy-shift LCD display
-ECO & advanced ECO mode
-Standard extra large charger
-Hot-swappable batteries
-Rack/Tower design
-Emergency Power Off Function (EPO




INPUT
Voltage Range
Line Loss
110V~300V AC@ (0~60%) Load; 140V~300V @(60~80%) Load; 176V~300V AC@ (80~100%) Load
Low Line Comeback
Low Line Loss Voltage +10V
High Line Comeback
High Line Loss Voltage -10V
Frequency Range
46Hz~54Hz@ 50Hz system; 56Hz~64Hz@ 60Hz system
Phase
Single phase with ground
Power Factor Correction
=0.99@ nominal voltage (100% load)
OUTPUT
Output Power Factor: 0.9
Output Voltage
208/220/230/240V AC Selectable
AC Voltage Regulation
±1%
Frequency Range (Synchronized Range)
46Hz~54Hz@ 50Hz system 56Hz~64Hz@ 60Hz system
Frequency Range (Batt. Mode)
50Hz±0.1Hz or 60Hz±0.1Hz
Overload
AC Mode: 100%~110%: 10min; 110%~130%: 1min; >130%: 1sec Battery Mode: 100%~110%: 30sec; 110%~130%: 10sec; >130%: 1sec
Current Crest Ratio
3:1 (max.)
Harmonic Distortion
=1% @ 100% Linear Load; =4% @100% Non-linear Load
Transfer Time
Line to Battery: 0ms Inverter to Bypass: 0ms Inverter to Eco: < 10ms
EFFICIENCY
ECO Mode (Advanced)
<94%
Battery Mode
<93%
BATTERY
Battery Number
Optional strings of 16 or 20 batteries
Typical Recharge Time
According to an external battery pack
Charging Current (max.)
4A ± 10%
COMMUNICATIONS & MANAGEMENT
Interface
USB and RS232 as standard
Software
PowerShield® NetGuard® software - supports Windows, Linux, Unix and Mac based operating systems
Optional
Intelligent slot for PSSNMPV4, PSModbus or PSAS400 dry contact
PHYSICAL
Dimensions (D x W x H)
UPS Unit: 600x438x88mm [2U] (weight: 17kg) PSRTBB16 (16 batteries): 688x438x88mm [2U] (weight: 48kg) PSRTBB20 (20 batteries): 607x438x133mm [3U] (weight: 60kg)
OPERATING ENVIRONMENT
Temperature
0°C~40°C
Humidity
95% (RH Non-condensing)
Altitude
<1000m
Noise Level
Less than 55dB@ 1m


Manufacturer Part No:

PSCERT6000L
Brand:

PowerShield

Product Type:

-
UPC

-
Product Family:

-
Shipping Weight:

30 kg
PB Part No:

UPSPSD0030
Product Model:

-



Warranty:
24 months *
* Warranty period is as stated above unless the manufacturer has chosen to specify a longer period.
All warranties are return to base unless otherwise specified.

Questions?

In order to assist us in reducing spam, please type the characters you see:

You may also like